This appendix lists all the error messages that can appear on the emulation status line, and suggests corrective actions. The format is as follows:
First, all the corrective actions are listed.
Next, all the messages in numeric order are listed. Each message explanation includes:
A probable cause. IBM SNA sense data associated with the situation. A reference to one of the corrective actions.
When a message appears at the PC during emulation, write it down or print the PC screen. Then, look it up in the "Messages" section below. Find the corrective action indicated for that message in the following section, "Corrective Actions."
A Data stream errors. Contact your applications programming personnel.
B Configuration problem. Contact your VTAM/NCP systems programming personnel.
C System software is inconsistent. Contact your systems operation personnel.
D Device is in an inactive or a suspended state. Contact your systems operation personnel.
E 3270/SNA service is inconsistent. If stopping and restarting the service does not correct the problem, report the symptoms to Banyan.
1 Negative response received from HOST. Sense data is displayed. Use corrective action A.
2 Received an unsupported DFC (data flow control) request. The unsupported request code is displayed. Use corrective action B.
3 Your device has not been activated. Possibly, your device has been placed in an inactive state due to some communications error. Use corrective action D.
4 Your device has not been activated. Possibly, your device has been placed in an inactive state due to some communications error. Use corrective action D.
5 DFC (data flow control) receive check. The request code on a response does not match the original response. SNA receive check sense data 4012 (hex) is displayed. This should never happen and indicates that either mainframe or VINES software is in an inconsistent state. Use corrective action C.
6 DFC (data flow control) receive check. Both BC and EC must be included on a normal flow response. SNA receive check sense data 400b (hex) is displayed. Use corrective action C.
7 DFC (data flow control) receive check. Incorrect specification of RU category. SNA receive check sense data 4011 (hex) is displayed. Use corrective action C.
8 DFC (data flow control) receive check. The request code on a response does not match the original response. SNA receive check sense data 4012 (hex) is displayed. This should never happen and indicates that either mainframe or VINES software is in an inconsistent state. Use corrective action C.
9 DFC (data flow control) receive check. Incorrect specification of RU category. SNA receive check sense data 4011 (hex) is displayed. Use corrective action C.
10 DFC (data flow control) receive check. The request code on a response does not match the original response. SNA receive check sense data 4012 (hex) is displayed. This should never happen and indicates that either mainframe or VINES software is in an inconsistent state. Use corrective action C.
11 DFC (data flow control) receive check. Incorrect specification of RU category. SNA receive check sense data 4011 (hex) is displayed. Use corrective action C.
12 DFC (data flow control) receive check. Incorrect use of format indicator. SNA receive check sense data 400F (hex) is displayed. Use corrective action C.
13 DFC (data flow control) receive check. Both BC and EC must be included on a normal flow response. SNA receive check sense data 400b (hex) is displayed. Use corrective action C.
14 DFC (data flow control) receive check. Incorrect use of response indicators. SNA receive check sense data 4014 (hex) is displayed. Use corrective action C.
15 DFC (data flow control) receive check. Incorrect use of QRI. SNA receive check sense data 4015 (hex) is displayed. Use corrective action C.
16 DFC (data flow control) receive check. Incorrect use of bracket indicators. SNA receive check sense data 400C (hex) is displayed. Use corrective action C.
17 DFC (data flow control) receive check. The change direction indicator was incorrectly specified. SNA receive check sense data 4009 (hex) is displayed. Use corrective action C.
18 DFC (data flow control) receive check. Alternate code selection is not supported. SNA receive check sense data 4010 (hex) is displayed. Use corrective action B.
19 DFC (data flow control) receive check. Enciphered data indicator was incorrectly used. SNA receive check sense data 4016 (hex) is displayed. Use corrective action B.
20 DFC (data flow control) receive check. Padded data indicator was incorrectly used. SNA receive check sense data 4017 (hex) is displayed. Use corrective action B.
21 DFC (data flow control) receive check. An unsupported DFC request was received. SNA receive check sense data 1003 (hex) is displayed. Use corrective action B.
22 DFC (data flow control) receive check. An unsupported SIG request was received. Only the request-to-send form is supported. SNA receive check sense data 1003 (hex) is displayed. Use corrective action B.
23 DFC (data flow control) receive check. Incorrect use of format indicator. The format indicator was not set on a DFC request. SNA receive check sense data 400f (hex) is displayed. Use corrective action B.
24 DFC (data flow control) receive check. Chaining not supported. BC and EC must be set on DFC requests. SNA receive check sense data 400b (hex) is displayed. Use corrective action B.
25 DFC (data flow control) receive check. Alternate code set is not supported on DFC requests. SNA receive check sense data 4010 (hex) is displayed. Use corrective action B.
26 DFC (data flow control) receive check. Enciphered data indicator is not supported on DFC requests. SNA receive check sense data 4016 (hex) is displayed. Use corrective action B.
27 DFC (data flow control) receive check. Padded data indicator is not supported on DFC requests. SNA receive check sense data 4017 (hex) is displayed. Use corrective action B.
28 DFC (data flow control) receive check. Incorrect use of DRI1, DRI2, or ERI with BID, BIS, or RTR. SNA receive check sense data 4014 (hex) is displayed. Use corrective action B.
29 DFC (data flow control) receive check. Incorrect use of EB or BB with BID, BIS, or RTR request. SNA receive check sense data 400c (hex) is displayed. Use corrective action B.
30 DFC (data flow control) receive check. Incorrect use of CDI with BID, BIS, or RTR request. SNA receive check sense data 4009 (hex) is displayed. Use corrective action B.
31 DFC (data flow control) receive check. Incorrect use of DRI1, DRI2, or ERI with CANCEL, QC, or CHASE request. SNA receive check sense data 4014 (hex) is displayed. Use corrective action B.
32 DFC (data flow control) receive check. BB is not allowed with CANCEL, QC, or CHASE request. SNA receive check sense data 4003 (hex) is displayed. Use corrective action B.
33 DFC (data flow control) receive check. CDI is not allowed on CANCEL, QC, or CHASE request. SNA receive check sense data 4009 (hex) is displayed. Use corrective action B.
34 DFC (data flow control) receive check. An unsupported normal flow DFC request was received. SNA receive check sense data 1003 (hex) is displayed. Use corrective action B.
35 DFC (data flow control) receive check. Brackets not supported. SNA receive check sense data 400c (hex) is displayed. Use corrective action B.
36 DFC (data flow control) receive check. Received CDI with no ECI on normal flow FMD request. SNA receive check sense data 4009 (hex) is displayed. Use corrective action C.
37 DFC (data flow control) receive check. Begin bracket was specified incorrectly on a normal flow FMD request. SNA receive check sense data 4003 (hex) is displayed. Use corrective action C.
38 DFC (data flow control) receive check. End bracket was specified incorrectly on a normal flow FMD request. SNA receive check sense data 4004 (hex) is displayed. Use corrective action C.
39 DFC (data flow control) receive check. This implementation does not support the format indicator on normal flow FMD requests. Sense data 400f (hex) is displayed. Use corrective action B.
40 DFC (data flow control) receive check. This implementation does not support alternate code selection on normal flow FMD requests. Sense data 4010 (hex) is displayed. Use corrective action B.
41 DFC (data flow control) receive check. Brackets selected when BIND indicated brackets would not be used. Sense data 400c (hex) is displayed. Use corrective action B.
42 DFC (data flow control) receive check. Chaining indicators were incorrectly used when BIND indicated the multi-request chains would not be used. Sense data 400b (hex) is displayed. Use corrective action B.
43 DFC (data flow control) receive check. Definite response was requested when not permitted. Sense data 4007 (hex) is displayed. Use corrective action B.
44 DFC (data flow control) receive check. Exception response was requested when not permitted. Sense data 4006 (hex) is displayed. Use corrective action B.
45 DFC (data flow control) receive check. No response was requested when not permitted. Sense data 400a (hex) is displayed. Use corrective action B.
46 DFC (data flow control) receive check. Mode inconsistent with request. SHUTD request received when processing of a previous SHUTD request was pending. Sense data 0809 (hex) is displayed. Use corrective action C.
47 DFC (data flow control) receive check. Immediate request mode error. Sense data 200a (hex) is displayed. Use corrective action C.
48 DFC (data flow control) receive check. Half-duplex flip-flop direction error. Sense data 2004 (hex) is displayed. Use corrective action C.
49 DFC (data flow control) receive check. Contention error. Sense data 081b (hex) is displayed. This error should be ignored. Contention errors are resolved in favor of the 3270/SNA service.
50 DFC (data flow control) receive check. Chaining error. Sense data 2002 (hex) is displayed. Use corrective action C.
51 DFC (data flow control) receive check. Bracket error. Sense data 2003 (hex) is displayed. Use corrective action C.
52 DFC (data flow control) receive check. Bracket state error. Sense data 080b or 0813 (hex) is displayed. This error should be ignored.
53 DFC (data flow control) send check. Response owed before sending request. Sense data 200d is displayed Use corrective action E.
54 DFC (data flow control) send check. Improper use of change direction indicator. Sense data 4009 (hex) is displayed. Use corrective action E.
55 DFC (data flow control) send check. Immediate request mode error. Sense data 200a (hex) is displayed. Use corrective action E.
56 DFC (data flow control) send check. Chaining error. Sense data 2002 (hex) is displayed. Use corrective action E.
57 DFC (data flow control) send check. Half-duplex/flip-flop direction error. Sense data 2004 (hex) is displayed. Use corrective action E.
58 DFC (data flow control) send check. Bracket error. Sense data 2003 (hex) is displayed. Use corrective action E.
59 DFC (data flow control) send check. Mode inconsistency. Sense data 0809 (hex) is displayed. Use corrective action E.
60 DFC (data flow control) send check. Data traffic stopped for some reason. Sense data 2006 (hex) is displayed. Use corrective E.
62 NAU checks. Mode inconsistency, that is, request type-session mismatch. Sense data 0809 (hex) is displayed. Use corrective action B.
63 NAU checks. Received ACTLU request while PU is inactive. Sense data 8008 (hex) is displayed. Use corrective action C.
64 NAU checks. Received ACTLU request while LU is inactive. Sense data 8009 (hex) is displayed. Use corrective action C.
65 NAU checks. Received DACTPU request while PU is inactive. Sense data 8008 (hex) is displayed. Use corrective action C.
66 NAU checks. Received UNBIND request while PU is inactive. Sense data 8008 (hex) is displayed. Use corrective action C.
69 NAU checks. Received ACTPU request containing an unsupported activation type. Sense data 0835 (hex) is displayed. Use corrective action B.
70 NAU checks. Received ACTPU request containing an unsupported FM profile type. Sense data 0835 (hex) is displayed. Use corrective action B.
71 NAU checks. Received ACTPU request containing an unsupported TS profile type. Sense data 0835 (hex) is displayed. Use corrective action B.
72 NAU checks. Received ACTLU request while PU is not activated. Sense data 8008 (hex) is displayed. Use corrective action C.
73 NAU checks. Received ACTLU request for unassigned LU. Sense data 8009 (hex) is displayed. Use corrective action E.
74 NAU checks. Received badly formatted ACTLU request. Sense data 0835 (hex) is displayed. Use corrective action C.
75 NAU checks. Received ACTLU request containing an unsupported FM profile type. Sense data 0835 (hex) is displayed. Use corrective action B.
76 NAU checks. Received ACTLU request containing an unsupported TS profile type. Sense data 0835 (hex) is displayed. Use corrective action B.
77 NAU checks. Received BIND request while PU is not activated. Sense data 8008 (hex) is displayed. Use corrective action C.
78 NAU checks. Received BIND request while LU is not activated. Sense data 8009 (hex) is displayed. Use corrective action C.
79 NAU checks. Received BIND request while LU is already bound. Sense data 0815 (hex) is displayed. Use corrective action C.
80 NAU checks. Received BIND request which would exceed the LU session limit. Sense data 0805 (hex) is displayed. Use corrective action C.
81 NAU checks. Received BIND with an unsupported format. Sense data 0805 (hex) is displayed. Use corrective action B.
82 NAU checks. Received BIND request containing an unsupported FM profile type. Sense data 0835 (hex) is displayed. Use corrective action B.
83 NAU checks. Received BIND request containing an unsupported TS profile type. Sense data 0835 (hex) is displayed. Use corrective action B.
84 NAU checks. Illegal session control state. Sense data 2009 (hex) is displayed. Use corrective action B.
85 NAU checks. An ACTPU request for other than a cold start was received. Sense data 1003 (hex) is displayed. Use corrective action B.
86 NAU checks. An ACTPU request containing invalid session parameters was received. Sense data 0821 (hex) is displayed. Use corrective action B.
87 NAU checks. Received BIND request while LU is already bound. Sense data 0815 (hex) is displayed. Use corrective action C.
88 NAU checks. Received BIND request that would exceed the LU session limit. Sense data 0805 (hex) is displayed. Use corrective action C.
89 NAU checks. A BIND request for an unavailable LU was received. Sense data 0845 (hex) is displayed. Use corrective action B.
90 NAU checks. A BIND request containing illegal profiles was received. Sense data 0821 (hex) is displayed. Use corrective action B.
91 NAU checks. Mode inconsistency. Sense data 0809 (hex) is displayed. Use corrective action B.
92 NAU checks. Category not supported. Sense data 1007 (hex) is displayed. Use corrective action B.
93 NAU checks. SSCP-LU data flow in wrong session status. Sense data 0857 (hex) is displayed. Use corrective action C.
94 NAU checks. An unsupported session control request was received. Sense data 1003 (hex) is displayed. Use corrective action B.
95 NAU checks. An unsupported BIND request was received. Sense data 0821 (hex) is displayed. Use corrective action B.
96 TC receive checks. A request was received; however, the PU is not active. Sense data 8008 (hex) is displayed. Use corrective action C.
97 TC receive checks. A request was received; however, the LU is not active. Sense data 8009 (hex) is displayed. Use corrective action C.
98 TC receive checks. A request was received; however, the LU is not bound. Sense data 8005 (hex) is displayed. Use corrective action C.
99 TC receive checks. A DFC or FMD request was received; however, the session was never reset with a SDT request. Sense data 2005 (hex) is displayed. Use corrective action C.
100 TC receive checks. A request containing an unsupported request category was received. Sense data 1007 (hex) is displayed. Use corrective action B.
101 TC receive checks. The immediate request mode protocol was violated by the request. Sense data 200a (hex) is displayed. Use corrective action C.
102 TC receive checks. A pacing request was received but the session was bound with pacing off. Sense data 4008 (hex) is displayed. Use corrective action C.
103 TC receive checks. A nonsequential sequence number was received. Sense data 2001 (hex) is displayed. Use corrective action C.
104 TC receive checks. An SDT request was received; however, the LU does not support the SDT request. Sense data 1003 (hex) is displayed. Use corrective action E.
105 TC receive checks. An SDT request was received which cannot be actioned in the present state. Sense data 0809 (hex) is displayed. Use corrective action C.
106 TC receive checks. A CLEAR request was received; however, the LU does not support the CLEAR request. Sense data 1003 (hex) is displayed. Use corrective action E.
107 TC receive checks. An STSN request was received; however, the LU does not support the STSN request. Sense data 1003 (hex) is displayed. Use corrective action B.
108 TC receive checks. An STSN request was received, and the LU supports it; however, data traffic state is not reset. Sense data 2007 (hex) is displayed. Use corrective action E.
109 TC receive checks. An RQR request was received; however, the LU does not support it. Sense data 1003 (hex) is displayed. Use corrective action B.
110 TC receive checks. A CRV request was received; however, the LU does not support it. Sense data 1003 (hex) is displayed. Use corrective action B.
111 TC send checks. The immediate request mode protocol was violated. Sense data 200A (hex) is displayed, unless SNA SIG request is being processed. Use corrective action E.
112 TC send checks. Attempted to send a request while data traffic was not active. Sense data 2005 (hex) is displayed. Use corrective action E.
113 NAU check. RU is too long. Sense data 1002 (hex) is displayed. Use corrective action C.
114 Path Control check. Segmentation error. Sense data 8007 (hex) is displayed. Use corrective action C.
115 Path Control check. Segmentation error. Sense data 8007 (hex) is displayed. Use corrective action C.
116 Path Control check. OIS doesn't contain TH and RH. Sense data 8002 (hex) is displayed. Use corrective action C.
117 Path Control check. Segmentation error. Sense data 8007 (hex) is displayed. Use corrective action C.
118 Path Control check. Segmentation error. Sense data 8007 (hex) is displayed. Use corrective action C.
119 Path Control check. Segmentation error. Sense data 8007 (hex) is displayed. Use corrective action C.
120 Path Control check. Segmentation error. Sense data 8007 (hex) is displayed. Use corrective action C.
121 Path Control check. Segmentation error. Sense data 8007 (hex) is displayed. Use corrective action C.
122 Path Control check. Invalid address combination. Sense data 800f (hex) is displayed. Use corrective action B.
123 Path Control check. Invalid address/RU category combinations. Sense data 8003 (hex) is displayed. Use corrective action B.
124 Path Control check. PU is not active. Sense data 8008 (hex) is displayed. Use corrective action C.
125 Path Control check. LU is not active. Sense data 8009 (hex) is displayed. Use corrective action C.
126 Path Control check. No session bound. Sense data 8005 (hex) is displayed. Use corrective action C.
127 Path Control check. Incomplete TH. Sense data 800b (hex) is displayed. Use corrective action C.
128 Path Control check. Unrecognized destination address. Sense data 8004 (hex) is displayed. Use corrective action C.
129 Path Control check. Invalid FID. Sense data 8006 (hex) is displayed. Use corrective action C.
130 Path control check. Invalid FID. Sense data 8004 (hex) is displayed. Use corrective action C.
400 Data stream validation. An unknown 3270 data stream command was received. Sense data 1003 (hex) is displayed. Use corrective action A.
401 Data stream validation. Change direction was not set in a chain containing a read buffer, read modified, or read modified command. Sense data 0829 (hex) is displayed. Use corrective action A.
402 Data stream validation. The WCC of a type 3 data stream contained an unknown print format. Sense data 1001 (hex) is displayed. Use corrective action A.
404 Data stream validation. Additional data was encountered after a read buffer command. Sense data 1003 (hex) is displayed. Use corrective action A.
405 Data stream validation. Additional data was encountered after a read modified command. Sense data 1003 (hex) is displayed. Use corrective action A.
406 Data stream validation. Additional data was encountered after a read-modified-all command. Sense data 1003 (hex) is displayed. Use corrective action A.
407 Data stream validation. The chain terminated before all bytes of an order were received. For instance, an SBA order was received with a 1 byte cursor address. Sense data 1005 (hex) is displayed. Use corrective action A.
408 Data stream validation. An FMH1 header was received in a type 1 data stream. They are not supported by this implementation. Sense data 400f (hex) is displayed. Use corrective action A.
409 Data stream validation. An unsupported order was received in a type 1 or type 3 data stream. Sense data 1003 (hex) is displayed. Use corrective action A.
410 Data stream validation. A modify field order was received when the buffer address did not point to the start of a field. Sense data 0863 (hex) is displayed. Use corrective action A.
411 Data stream validation. A set attribute order was received containing a type C0 (hex) field attribute. Sense data 1003 (hex) is displayed. Use corrective action A.
412 Data stream validation. An unknown highlight value was received in a set attribute, modify field, or start field extended order. Sense data 1003 (hex) is displayed. Use corrective action A.
413 Data stream validation. An unknown color value was received in a set attribute, modify field, or start field extended order. Sense data 1003 (hex) is displayed. Use corrective action A.
414 Data stream validation. An unknown type was received in a set attribute, modify field, or start field extended order. Sense data 1003 (hex) is displayed. Use corrective action A.
415 Data stream validation. An invalid address was received in a set buffer address order. Sense data 1005 (hex) is displayed. Use corrective action A.
416 Data stream validation. An invalid address was received in a repeat to address order. Sense data 1005 (hex) is displayed. Use corrective action A.
417 Data stream validation. An invalid address was received in an erase unprotected order. Sense data 1005 (hex) is displayed. Use corrective action A.
418 Data stream validation. A type 1 set order 2b (hex) was not followed by a set horizontal format, set vertical format, or set line density code. Sense data 1005 (hex) is displayed. Use corrective action A.
419 Data stream validation. An unknown type 1 stream order was received. Sense data 1005 (hex) is displayed. Use corrective action A.
420 Data stream validation. A WCC start print bit was encountered in a structured field of type 3270DS where the structured field was not the last structured field in the chain. Sense data 1001 (hex) is displayed. Use corrective action A.
421 Data stream validation. An unknown structured field type was encountered. Sense data 1003 (hex) is displayed. Use corrective action A.
422 Data stream validation. A read partition structured field was received, for which the partition id was not ff (hex). Sense data 1005 (hex) is displayed. Use corrective action A.
423 Data stream validation. A read partition structured field was received which was not a query request. Sense data 1003 (hex) is displayed. Use corrective action A.
424 Data stream validation. A read partition structured field was received in a request that did not contain the change direction indicator. Sense data 0829 (hex) is displayed. Use corrective action A.
425 Data stream validation. A set response mode structured field was received for which the partition id was not zero. Sense data 1003 (hex) is displayed. Use corrective action A.
426 Data stream validation. An unknown set response mode type was received. Sense data 1003 (hex) is displayed. Use corrective action A.
427 Data stream validation. A 3270DS structured field was received for which the partition id was not zero. Sense data 1005 is displayed. Use corrective action A.